CHILLED WATER FAN COILS
Horizontal concealed Vertical concealed Horizontal exposed Vertical exposed
AIR FLOW : 340÷2380 MCH
FEATURES
STRUCTURE
Panels
and frame are made from heavy gauge galvanized steel, properly punched and
right assemble.
HEAT EXCHANGER
The
coil is made of aluminum finned copper tube, optimum FPI increasing heat
transfer efficiency .The connections have brass header with female fittings and
equipped with air vent ,pipe into the drain pan.
FAN DECK
The
fan deck are composed of double inlet centrifugal fan and direct drive motor.
Each fan is statically and dynamically balanced to ensure quiet operation and
optimum performance..
DRAIN TRAY
Drain
tray is made from sheet metal treated with polyester powder painting anti
corrosion and well insulation anti condensate .
FILTER
Easy
removed filter is made of polypropylene fabric supported by aluminum frame,
which is washable type. The filter is installed on the units with plenum only.
OPTIONAL
1.
Electric heater 2. Return air plenum 3. Aluminum filter 4. Balancing valve 5.Two or three way Valve
TECHNICAL DATA
Horizontal / Vertical unit (2 pipes ,3 rows)
Performance parameters
Product
Type
|
FCU34
|
FCU51
|
FCU68
|
FCU85
|
FCU102
|
FCU136
|
FCU170
|
FCU204
|
FCU238
|
Air Flow
|
High
|
m3/h
|
340
|
510
|
680
|
850
|
1020
|
1360
|
1700
|
2040
|
2380
|
Middle
|
m3/h
|
279
|
418
|
558
|
697
|
836
|
1115
|
1394
|
1673
|
1952
|
Low
|
m3/h
|
170
|
255
|
340
|
425
|
510
|
680
|
850
|
1020
|
1190
|
Total
cooling capacity
|
High
|
W
|
2170
|
3120
|
4090
|
4920
|
6070
|
8210
|
9380
|
11800
|
12700
|
Middle
|
W
|
1953
|
2819
|
3738
|
4350
|
5452
|
7469
|
8535
|
10495
|
11175
|
Low
|
W
|
1579
|
2323
|
3010
|
3504
|
4384
|
6043
|
6889
|
8480
|
9270
|
Total
heating capacity
|
High
|
W
|
3497
|
5014
|
6738
|
7618
|
9760
|
13176
|
14812
|
18030
|
19700
|
Middle
|
W
|
3044
|
4358
|
5652
|
6817
|
8254
|
11297
|
12880
|
15737
|
17052
|
Low
|
W
|
2518
|
3710
|
4986
|
5637
|
7027
|
9486
|
10664
|
13161
|
13987
|
Fan motor
Input power
|
12Pa
|
W
|
34
|
46
|
55
|
70
|
87
|
117
|
140
|
181
|
223
|
30Pa
|
W
|
42
|
56
|
70
|
81
|
101
|
149
|
165
|
202
|
241
|
50Pa
|
W
|
46
|
65
|
82
|
89
|
109
|
163
|
201
|
228
|
286
|
Power Supply
|
|
V/PH/Hz
|
220/1/50
|
Noise
|
12Pa
|
dB(A)
|
36
|
38
|
40
|
42
|
44
|
45
|
47
|
49
|
51
|
30Pa
|
dB(A)
|
39
|
41
|
43
|
45
|
46
|
47
|
49
|
51
|
53
|
50Pa
|
dB(A)
|
41
|
43
|
45
|
46
|
48
|
49
|
51
|
53
|
55
|
Water
Flow
|
kg/h
|
373
|
536
|
703
|
846
|
1044
|
1412
|
1613
|
2029
|
2184
|
Water
Resistence
|
kPa
|
10
|
15
|
18
|
23
|
24
|
32
|
36
|
40
|
50
|
water
pipe connections
|
mm
|
ZG3/4"(DN20)
|
Draining
pipe
|
mm
|
Rc3/4"(DN20)
|
Dimension
(L×W×H)
|
Horizontal
concealed unit net
|
mm
|
770×466
×230
|
870×466
×230
|
970×466
×230
|
1070×466
×230
|
1170×466
×230
|
1370×466
×230
|
1470×466
×230
|
1870×466
×230
|
1870×466
×230
|
Horizontal
concealed package
|
mm
|
790×508
×250
|
890×508×250
|
990×508
×250
|
1090×508
×250
|
1190×508
×250
|
1390×508
×250
|
1490×508
×250
|
1890×508
×250
|
1890×508
×250
|
Horizontal
concealed with plenum net
|
mm
|
770×477
×230
|
870×477
×230
|
970×477
×230
|
1070×477
×230
|
1170×477
×230
|
1370×477
×230
|
1470×477
×230
|
1870×477
×230
|
1870×477
×230
|
Horizontal
concealed with plenum package
|
mm
|
790×508
×250
|
890×508
×250
|
990×508
×250
|
1090×508
×250
|
1190×508
×250
|
1390×508
×250
|
1490×508
×250
|
1890×508
×250
|
1890×508
×250
|
Horizontal
exposed
|
mm
|
790×510
×240
|
940×510
×240
|
1020×510
×240
|
1140×510
×240
|
1260×510
×240
|
1450×510
×240
|
1570×510
×240
|
1880×510
×240
|
1880×510
×240
|
Horizontal
exposed package
|
mm
|
820×560
×260
|
970×560
×260
|
1050×560
×260
|
1170×560
×260
|
1290×560
×260
|
1480×560
×260
|
1600×560
×260
|
1910×560
×260
|
1910×560
×260
|
Vertical concealed
|
mm
|
600×230
×610
|
680×230
×610
|
850×230
×610
|
935×230
×610
|
1060×230
×610
|
1255×230
×610
|
1355×230
×610
|
1720×230
×610
|
1720×230
×610
|
Vertical concealed package
|
mm
|
630×250
×650
|
710×250
×650
|
880×250
×650
|
965×250
×650
|
1090×250
×650
|
1285×250
×650
|
1385×250
×650
|
1750×250
×650
|
1750×250
×650
|
Vertical
exposed
|
mm
|
790×240
×620
|
940×240
×620
|
1100×240
×620
|
1140×240
×620
|
1260×240
×620
|
1450×240
×620
|
1570×240
×620
|
1920×240
×620
|
1920×240
×620
|
Vertical
exposed package
|
mm
|
820×260
×660
|
970×260
×660
|
1130×260
×660
|
1170×260
×660
|
1290×260
×660
|
1480×260
×660
|
1600×260
×660
|
1950×260
×660
|
1950×260
×660
|
Weight
|
Horizontal
concealed
|
Kg
|
13
|
15
|
17.5
|
19
|
21
|
29
|
31.5
|
36
|
36
|
Horizontal
concealed with plenum
|
Kg
|
15.5
|
18
|
21.5
|
23
|
25.5
|
35
|
37.5
|
44
|
44
|
Horizontal
exposed
|
Kg
|
23
|
26
|
28
|
32
|
35
|
44
|
45.5
|
56
|
56
|
Vertical concealed
|
Kg
|
21
|
24
|
25
|
26
|
30
|
36
|
45
|
47
|
47
|
Vertical
exposed
|
Kg
|
26
|
29
|
32
|
35
|
40
|
47.5
|
49.5
|
59
|
59
|
Performance values
refer to the following conditions:
*Cooling capacity is measured under the condition : Ambient
temperature DB 27℃/WB
19.5℃ ,
water inlet/outlet temperature 7℃/ 12℃
*Heating capacity is
measured under the condition : Ambient temperature DB 21℃, water inlet
temperature 60℃
TECHNICAL DATA
Horizontal / Vertical unit (4 pipes, 3+1 rows)
Performance parameters
Product
Type
|
FCU34
|
FCU51
|
FCU68
|
FCU85
|
FCU102
|
FCU136
|
FCU170
|
FCU204
|
FCU238
|
Air Flow
|
High
|
m3/h
|
340
|
510
|
680
|
850
|
1020
|
1360
|
1700
|
2040
|
2380
|
Middle
|
m3/h
|
279
|
418
|
558
|
697
|
836
|
1115
|
1394
|
1673
|
1952
|
Low
|
m3/h
|
170
|
255
|
340
|
425
|
510
|
680
|
850
|
1020
|
1190
|
Total
cooling capacity
|
High
|
W
|
2110
|
3040
|
3980
|
4810
|
5950
|
7980
|
9160
|
11500
|
12600
|
Middle
|
W
|
1890
|
2750
|
3640
|
4250
|
5350
|
7290
|
8350
|
10100
|
11020
|
Low
|
W
|
1530
|
2260
|
2920
|
3410
|
4290
|
5870
|
6720
|
8180
|
9260
|
Total
heating capacity
|
High
|
W
|
2040
|
2910
|
3910
|
4470
|
5330
|
7460
|
8740
|
11060
|
11700
|
Middle
|
W
|
1770
|
2530
|
3280
|
4000
|
4510
|
6400
|
7600
|
9650
|
10120
|
Low
|
W
|
1470
|
2150
|
2890
|
3300
|
3830
|
5370
|
6290
|
8070
|
8300
|
Fan motor
Input power
|
12Pa
|
W
|
34
|
46
|
55
|
70
|
87
|
117
|
140
|
181
|
223
|
30Pa
|
W
|
42
|
56
|
70
|
81
|
101
|
149
|
165
|
202
|
241
|
50Pa
|
W
|
46
|
65
|
82
|
89
|
109
|
163
|
201
|
228
|
286
|
Power Supply
|
|
V/PH/Hz
|
220/1/50
|
Noise
|
12Pa
|
dB(A)
|
36
|
38
|
40
|
42
|
44
|
45
|
47
|
49
|
51
|
30Pa
|
dB(A)
|
39
|
41
|
43
|
45
|
46
|
47
|
49
|
51
|
53
|
50Pa
|
dB(A)
|
41
|
43
|
45
|
46
|
48
|
49
|
51
|
53
|
55
|
Chilled
water Flow
|
kg/h
|
360
|
520
|
690
|
830
|
1020
|
1370
|
1580
|
1980
|
2170
|
hot water Flow
|
kg/h
|
180
|
250
|
340
|
380
|
460
|
640
|
750
|
950
|
1010
|
Chilled
water Resistence
|
kPa
|
10
|
15
|
18
|
23
|
24
|
32
|
36
|
40
|
50
|
hot water
Resistence
|
kPa
|
6
|
10
|
12
|
18
|
20
|
24
|
27
|
30
|
36
|
water
pipe connections
|
mm
|
Rc3/4"(DN20)
|
Draining
pipe
|
mm
|
Rc3/4"(DN20)
|
Dimension
(L×W×H)
|
Horizontal
concealed
|
mm
|
770×466×230
|
870×466×230
|
970×466×230
|
1070×466×230
|
1170×466×230
|
1370×466×230
|
1470×466×230
|
1870×466×230
|
1870×466×230
|
Horizontal
concealed package
|
mm
|
790×508×250
|
890×508×250
|
990×508×250
|
1090×508×250
|
1190×508×250
|
1390×508×250
|
1490×508×250
|
1890×508×250
|
1890×508×250
|
Horizontal
concealed with plenum
|
mm
|
770×477×230
|
870×477×230
|
970×477×230
|
1070×477×230
|
1170×477×230
|
1370×477×230
|
1470×477×230
|
1870×477×230
|
1870×477×230
|
Horizontal
concealed with plenum package
|
mm
|
790×508×250
|
890×508×250
|
990×508×250
|
1090×508×250
|
1190×508×250
|
1390×508×250
|
1490×508×250
|
1890×508×250
|
1890×508×250
|
Horizontal
exposed
|
mm
|
790×510×240
|
940×510×240
|
1020×510×240
|
1140×510×240
|
1260×510×240
|
1450×510×240
|
1570×510×240
|
1880×510×240
|
1880×510×240
|
Horizontal
exposed package
|
mm
|
820×560×260
|
970×560×260
|
1050×560×260
|
1170×560×260
|
1290×560×260
|
1480×560×260
|
1600×560×260
|
1910×560×260
|
1910×560×260
|
Vertical concealed
|
mm
|
600×230×610
|
680×230×610
|
850×230×610
|
935×230×610
|
1060×230×610
|
1255×230×610
|
1355×230×610
|
1720×230×610
|
1720×230×610
|
Vertical concealed package
|
mm
|
630×250×650
|
710×250×650
|
880×250×650
|
965×250×650
|
1090×250×650
|
1285×250×650
|
1385×250×650
|
1750×250×650
|
1750×250×650
|
Vertical
exposed
|
mm
|
790×240×620
|
940×240×620
|
1100×240×620
|
1140×240×620
|
1260×240×620
|
1450×240×620
|
1570×240×620
|
1920×240×620
|
1920×240×620
|
Vertical
exposed package
|
mm
|
820×260×660
|
970×260×660
|
1130×260×660
|
1170×260×660
|
1290×260×660
|
1480×260×660
|
1600×260×660
|
1950×260×660
|
1950×260×660
|
Weight
|
Horizontal
concealed
|
Kg
|
13.5
|
15.5
|
18
|
20
|
22
|
30
|
33
|
38
|
38
|
Horizontal
concealed with plenum
|
Kg
|
16
|
18.5
|
22
|
24
|
26.5
|
36
|
39
|
46
|
46
|
Horizontal
exposed
|
Kg
|
24
|
27
|
29
|
33
|
36
|
45.5
|
47
|
58
|
58
|
Vertical concealed
|
Kg
|
22
|
25
|
26
|
27
|
31
|
37
|
46
|
48
|
48
|
Vertical
exposed
|
Kg
|
27
|
30
|
33
|
36
|
41
|
49
|
51
|
61
|
61
|
Performance values
refer to the following conditions:
*Cooling capacity is measured under the condition : Ambient
temperature DB 27℃/WB
19.5℃ ,
water inlet/outlet temperature 7℃/ 12℃
*Heating capacity is
measured under the condition : Ambient temperature DB 21℃, water inlet
temperature 60℃
|